Object Tracking on Medical X-ray Catheter Tip (test)
1.21RMSE MeanHiFT
Evaluation Results
| Method | Links | |||||
|---|---|---|---|---|---|---|
| HiFTinitialization=Manual2025.01 | 1.21 | 1.04 | 0.68 | 4.04 | 28 | |
| SimSTinitialization=Manual2025.01 | 1.44 | 1.02 | 1.35 | 10.23 | 42 | |
| HiFTinitialization=Automatic2025.01 | 1.45 | 1.05 | 1.3 | 9.29 | 28 | |
| ConTrackinitialization=Manual2025.01 | 1.63 | 1.08 | 1.7 | 13.32 | 12 | |
| SimSTinitialization=Automatic2025.01 | 2.24 | 1.61 | 2.19 | 18.66 | 42 | |
| Cycle YNetinitialization=Manual2025.01 | 2.68 | 1.96 | 2.4 | 21.04 | 109 | |
| ConTrackinitialization=Automatic2025.01 | 2.87 | 2.29 | 2.36 | 17.26 | 12 | |
| Starkinitialization=Manual2025.01 | 4.14 | 2.65 | 4.93 | 31.34 | 22 | |
| Mixformerinitialization=Manual2025.01 | 5.15 | 2.68 | 7.1 | 49.29 | 20 | |
| SiameseRPNinitialization=Manual2025.01 | 9.01 | 7.13 | 6.81 | 46.23 | 18 | |
| 3D-DenseUNetinitialization=Automatic2025.01 | 9.75 | 7.38 | 7.01 | 53.56 | 87 |