List your company

Undersampled MRI Reconstruction on Brain MRI

43.16PSNR (dB)Proposed
20.716826.543432.3738.1966Mar 9, 2021

Evaluation results

MethodLinks
ProposedAcceleration rate=4x2021.0343.1698.28
w/o MDAcceleration rate=4x2021.0342.898.17
IndependentAcceleration rate=4x2021.0340.8597.3
SharedAcceleration rate=4x2021.0340.7897.3
ProposedAcceleration rate=6x2021.0340.0397.02
w/o MDAcceleration rate=6x2021.0339.4996.63
IndependentAcceleration rate=6x2021.0338.0495.48
SharedAcceleration rate=6x2021.0337.5194.9
UndersampledAcceleration rate=4x2021.0331.678.69
UndersampledAcceleration rate=6x2021.0321.5858.47