List your company

System Identification on Magneto-rheological fluid damper 1499 measurements (test)

7.12RMSESONIG
6.320811.715417.1122.5046Jan 29, 2016

Evaluation results

MethodLinks
SONIGinducing input points=322016.017.12
RR GP-SSM2016.018.17
NLARXModel order=3rd order, Model structure=sigmoid network2016.018.24
GP regressionModel structure=ARX model (1)2016.019.87
NIGPModel structure=ARX model (1)2016.0110.2
NLARXModel order=3rd order, Model structure=tree partition2016.0119.3
NLARXModel order=3rd order, Model structure=wavelet network2016.0124.5
Hammerstein-WienerModel order=4th order2016.0127
Linear OE modelModel order=4th order2016.0127.1