PAT Reconstruction on Simulated phantom data 0% L2-noise
19.316PSNR (dB)DIP early stopping
Evaluation Results
| Method | Links | |||||
|---|---|---|---|---|---|---|
| DIP early stoppingRegularization method=DIP, Convergence status=early stopping, Detector coverage=270°2026.04 | 19.316 | 83.9 | 0.135 | 96.1 | 42.7 | |
| TVRegularization method=TV, Detector coverage=270°2026.04 | 18.742 | 62.6 | 0.084 | 96.9 | 54 | |
| DIP convergedRegularization method=DIP, Convergence status=converged, Detector coverage=270°2026.04 | 18.598 | 71.4 | 0.097 | 96.9 | 53.1 | |
| Initial (FFT)FFT initialization=true, Detector coverage=270°2026.04 | 18.475 | 71.1 | 0.079 | 97 | 53.3 |