List your company

MRI Reconstruction on OCMR AF=8x (test)

29.74PSNR (dB)L+S DIP
21.57623.695525.81527.9345Feb 15, 2026Mar 2, 2026Mar 17, 2026Apr 2, 2026Apr 17, 2026May 2, 2026May 18, 2026

Evaluation results

MethodLinks
L+S DIPTraining data=Not needed2026.0529.74—90
L+S-NetTraining data=Needed2026.0528.32—87
LR-DIPTraining data=Not needed2026.0527.73—78
MostNetSampling Mask=dSUNO2026.0227.710.10377.3
MostNetSampling Mask=VISTA2026.0226.980.15876.8
CTFNetSampling Mask=VISTA2026.0226.640.16376.1
Fourier-feature INRTraining data=Not needed2026.0526.64—75
Multi-dynamic DIPTraining data=Not needed2026.0526.44—71
CTFNetSampling Mask=dSUNO2026.0225.830.19175.9
MostNetSampling Mask=VDRS2026.0225.430.21171.5
CTFNetSampling Mask=VDRS2026.0225.120.2270.2
Compressed sensingTraining data=Not needed2026.0524.48—74
CSSampling Mask=VDRS2026.0224.230.30571.1
SENSESampling Mask=Equispaced2026.0221.890.49270.4