0.626Contour Distance (Myocardium)VecHeart
Evaluation Results
| Method | Links | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VecHeartInput Part Masking=Missing LA, Resolution=1282026.04 | 0.626 | 97.65 | 0.29 | 98.99 | 0.386 | 98.82 | 1.938 | 92.89 | 0.246 | 98.82 | — | |
| VecHeartInput Part Masking=Missing RA, Resolution=1282026.04 | 0.626 | 97.65 | 0.289 | 99.02 | 0.387 | 98.79 | 0.212 | 98.94 | 1.229 | 94.18 | — | |
| VecHeartInput Part Masking=Missing LA & RA, Resolution=1282026.04 | 0.64 | 97.2 | 0.301 | 98.81 | 0.403 | 98.52 | 5.979 | 87.03 | 4.336 | 89.48 | — | |
| PartSDFInput Part Masking=Missing RA, Resolution=1282026.04 | 0.686 | 92.53 | 0.326 | 96.68 | 0.455 | 95.65 | 0.287 | 95.6 | 11.536 | 83.83 | 0.01 | |
| PartSDFInput Part Masking=Missing LA, Resolution=1282026.04 | 0.688 | 92.46 | 0.327 | 96.6 | 0.455 | 95.69 | 13.18 | 79.38 | 0.355 | 94.89 | 0.01 | |
| SDF4CHDInput Part Masking=Missing LA, Resolution=1282026.04 | 0.737 | 90.13 | 0.408 | 95.24 | 0.532 | 93.54 | 4.268 | 88.8 | 0.457 | 92.86 | 0.01 | |
| SDF4CHDInput Part Masking=Missing RA, Resolution=1282026.04 | 0.739 | 90.16 | 0.407 | 95.23 | 0.531 | 93.55 | 0.364 | 93.16 | 5.061 | 88.88 | 0.01 | |
| CardiacFlowInput Part Masking=Missing LA, Resolution=1282026.04 | 1.638 | 94.42 | 1.173 | 97.56 | 1.723 | 96.72 | 5.679 | 88.7 | 1.513 | 95.57 | 0.01 | |
| CardiacFlowInput Part Masking=Missing RA, Resolution=1282026.04 | 1.665 | 94.3 | 1.175 | 97.5 | 1.696 | 96.75 | 1.447 | 95.9 | 5.956 | 88.22 | 0.01 | |
| ImHeartInput Part Masking=Missing LA, Resolution=1282026.04 | 2.113 | 86.79 | 2.164 | 92.72 | 2.894 | 91.26 | 9.584 | 81.47 | 2.432 | 90.13 | 0.01 | |
| ImHeartInput Part Masking=Missing RA, Resolution=1282026.04 | 2.115 | 86.32 | 2.307 | 92.47 | 2.853 | 90.87 | 2.337 | 88.99 | 9.766 | 85.65 | 0.01 |