List your company

Cardiac MRI Reconstruction on 2D cardiac cine MRI (test)

36.26pSNRProposed MCMR
21.1550425.0765228.99832.91948Mar 6, 2021Jun 5, 2021Sep 5, 2021Dec 6, 2021Mar 8, 2022Jun 8, 2022Sep 8, 2022

Evaluation results

MethodLinks
Proposed MCMRAcceleration Rate=8, Execution Time=18.81s2022.0936.260.943—
Proposed MCMRAcceleration Rate=12, Execution Time=18.81s2022.0935.450.932—
GRAFT + CG-SENSEAcceleration Rate=8, Execution Time=6.27s2022.0934.930.913—
Proposed MCMRAcceleration Rate=16, Execution Time=18.81s2022.0934.780.927—
N-CG-SENSEAcceleration Rate=8, Execution Time=1.37s2022.0930.80.821—
2D+time MoDLMEL=true, unrolls=102021.0327.420.88831.64
2D+time MoDLunrolls=42021.0326.870.8736.93
Elastix + CG-SENSEAcceleration Rate=8, Execution Time=4281s2022.0925.040.645—
PICS2021.0324.690.82439.4
N-CG-SENSEAcceleration Rate=12, Execution Time=1.37s2022.0924.40.637—
Elastix + CG-SENSEAcceleration Rate=12, Execution Time=4281s2022.0923.510.568—
N-CG-SENSEAcceleration Rate=16, Execution Time=1.37s2022.0921.7360.531—