# VLM Judge Evaluation on VIABLE averaged over three corpora

Source: [VLM Judge Evaluation on VIABLE averaged over three corpora](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-06-01T10:05:04.078Z

Evaluation of Vision-Language Model (VLM) judging capabilities using the VIABLE benchmark, which aggregates results across three distinct corpora, focusing on robustness and preference metrics.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | VLM Judge Evaluation |
| Dataset (including any stated split) | VIABLE averaged over three corpora |
| Metric | Single-Injection Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 7 of 7 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Single-Injection Accuracy](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Single-Injection%20Accuracy>): Higher is better; unit: PERCENT.

- [Dual-Injection Accuracy (Full)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Dual-Injection%20Accuracy%20(Full)>): Higher is better; unit: PERCENT.

- [Dual-Injection Accuracy (Partial)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Dual-Injection%20Accuracy%20(Partial)>): Higher is better; unit: PERCENT.

- [Positional Accuracy (Rgt)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Positional%20Accuracy%20(Rgt)>): Higher is better; unit: PERCENT.

- [Positional Score (Rpos-A)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Positional%20Score%20(Rpos-A)>): Higher is better; unit: PERCENT.

- [Positional Score (Rpos-B)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Positional%20Score%20(Rpos-B)>): Higher is better; unit: PERCENT.

- [Length Accuracy (Rgt)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Length%20Accuracy%20(Rgt)>): Higher is better; unit: PERCENT.

- [Length Accuracy (Rlong)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Length%20Accuracy%20(Rlong)>): Higher is better; unit: PERCENT.

- [Self Preference Score (Rgt)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Self%20Preference%20Score%20(Rgt)>): Higher is better; unit: PERCENT.

- [Self Preference Score (Rself)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Self%20Preference%20Score%20(Rself)>): Higher is better; unit: PERCENT.

- [Consistency Score (Rcons)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Consistency%20Score%20(Rcons)>): Higher is better; unit: PERCENT.

- [Advantage Score (Rgt)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Advantage%20Score%20(Rgt)>): Higher is better; unit: PERCENT.

- [Advantage Score (Radv)](<https://www.sota2.com/research/sota/vlm-judge-evaluation-on-viable-averaged-over-three-corpora.md?metric=Advantage%20Score%20(Radv)>): Higher is better; unit: PERCENT.

## Recorded results

| Method | Single-Injection Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| GPT-5.4 | 52.6 | Not recorded | 6a1d1233dbd7150506f8413d |
| Claude-Sonnet-4.6 | 45.9 | Not recorded | 6a1d1233dbd7150506f8413d |
| Qwen3-VL-8B | 24.6 | Not recorded | 6a1d1233dbd7150506f8413d |
| InternVL3.5-8B | 24 | Not recorded | 6a1d1233dbd7150506f8413d |
| MiniCPM-V4.5-8B | 23.1 | Not recorded | 6a1d1233dbd7150506f8413d |
| Youtu-VL-4B | 21.6 | Not recorded | 6a1d1233dbd7150506f8413d |
| Kimi-VL-A3B | 14.9 | Not recorded | 6a1d1233dbd7150506f8413d |

### GPT-5.4

Single-Injection Accuracy: 52.6. Result ID: 6a1d58affbc373592c17194a.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### Claude-Sonnet-4.6

Single-Injection Accuracy: 45.9. Result ID: 6a1d58affbc373592c171949.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### Qwen3-VL-8B

Single-Injection Accuracy: 24.6. Result ID: 6a1d58affbc373592c171947.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa788e1e209131cea79116.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### InternVL3.5-8B

Single-Injection Accuracy: 24. Result ID: 6a1d58affbc373592c171948.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa7af01e209131cea85dc9.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### MiniCPM-V4.5-8B

Single-Injection Accuracy: 23.1. Result ID: 6a1d58affbc373592c171946.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa7b8d1e209131cea8913f.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### Youtu-VL-4B

Single-Injection Accuracy: 21.6. Result ID: 6a1d58affbc373592c171945.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

[Method origin paper](<https://www.sota2.com/research/paper/6979985ea2b28e761d87ce34.md>)

[Implementation](<https://github.com/TencentCloudADP/youtu-vl>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### Kimi-VL-A3B

Single-Injection Accuracy: 14.9. Result ID: 6a1d58affbc373592c171944.

[Reporting paper](<https://www.sota2.com/research/paper/6a1d1233dbd7150506f8413d.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa79a81e209131cea7eb7f.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
