A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Surgical Scene Understanding |
| Dataset (including any stated split) | Autolaparo |
| Metric | Phase Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 16 of 16 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Phase Accuracy](<https://www.sota2.com/research/sota/surgical-scene-understanding-on-autolaparo.md?metric=Phase%20Accuracy>): Higher is better; unit: PERCENT.

- [Tool/Keystep Accuracy](<https://www.sota2.com/research/sota/surgical-scene-understanding-on-autolaparo.md?metric=Tool%2FKeystep%20Accuracy>): Higher is better; unit: PERCENT.

## Recorded results

| Method | Phase Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| PeskaVLP | 63.1 | Not recorded | 68fa77691e209131cea731fe |
| Moco | 59.5 | Not recorded | 68fa77691e209131cea731fe |
| CLIP | 58.5 | Not recorded | 68fa77691e209131cea731fe |
| ImageNet | 57.5 | Not recorded | 68fa77691e209131cea731fe |
| HecVL | 56.9 | Not recorded | 68fa77691e209131cea731fe |
| SurgVLP | 54.3 | Not recorded | 68fa77691e209131cea731fe |
| CLIP | 53.1 | Not recorded | 68fa77691e209131cea731fe |
| PeskaVLP | 53.1 | Not recorded | 68fa77691e209131cea731fe |
| Moco | 51.3 | Not recorded | 68fa77691e209131cea731fe |
| Moco | 49.9 | Not recorded | 68fa77691e209131cea731fe |
| SurgVLP | 48.5 | Not recorded | 68fa77691e209131cea731fe |
| HecVL | 46.9 | Not recorded | 68fa77691e209131cea731fe |
| CLIP | 46.2 | Not recorded | 68fa77691e209131cea731fe |
| Moco | 45.4 | Not recorded | 68fa77691e209131cea731fe |
| CLIP | 45.3 | Not recorded | 68fa77691e209131cea731fe |
| ImageNet | 44.9 | Not recorded | 68fa77691e209131cea731fe |

### PeskaVLP

Phase Accuracy: 63.1. Result ID: 699488fe3a6c3148491ddbbd.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Implementation](<https://github.com/CAMMA-public/SurgVLP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (VL)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### Moco

Phase Accuracy: 59.5. Result ID: 699488fe3a6c3148491ddbb1.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa673f1e209131cea15344.md>)

[Implementation](<https://github.com/facebookresearch/moco>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (V)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### CLIP

Phase Accuracy: 58.5. Result ID: 699488fe3a6c3148491ddbb5.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa69581e209131cea21ad0.md>)

[Implementation](<https://github.com/OpenAI/CLIP>)

Recorded evaluation configuration: {"Pre-training Dataset":"NA (L)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### ImageNet

Phase Accuracy: 57.5. Result ID: 699488fe3a6c3148491ddbaf.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa61b41e209131ce9f58d2.md>)

Recorded evaluation configuration: {"Pre-training Dataset":"ImageNet (V)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### HecVL

Phase Accuracy: 56.9. Result ID: 699488fe3a6c3148491ddbbb.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731d1.md>)

[Implementation](<https://github.com/CAMMA-public/SurgVLP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### SurgVLP

Phase Accuracy: 54.3. Result ID: 699488fe3a6c3148491ddbb9.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa79841e209131cea7df69.md>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### CLIP

Phase Accuracy: 53.1. Result ID: 699488fe3a6c3148491ddbb7.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa69581e209131cea21ad0.md>)

[Implementation](<https://github.com/OpenAI/CLIP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### PeskaVLP

Phase Accuracy: 53.1. Result ID: 699488fe3a6c3148491ddbbe.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Implementation](<https://github.com/CAMMA-public/SurgVLP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (VL)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### Moco

Phase Accuracy: 51.3. Result ID: 699488fe3a6c3148491ddbb3.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa673f1e209131cea15344.md>)

[Implementation](<https://github.com/facebookresearch/moco>)

Recorded evaluation configuration: {"Pre-training Dataset":"Cholec80 (V)","%shot":"100","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### Moco

Phase Accuracy: 49.9. Result ID: 699488fe3a6c3148491ddbb2.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa673f1e209131cea15344.md>)

[Implementation](<https://github.com/facebookresearch/moco>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (V)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### SurgVLP

Phase Accuracy: 48.5. Result ID: 699488fe3a6c3148491ddbba.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa79841e209131cea7df69.md>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### HecVL

Phase Accuracy: 46.9. Result ID: 699488fe3a6c3148491ddbbc.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731d1.md>)

[Implementation](<https://github.com/CAMMA-public/SurgVLP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### CLIP

Phase Accuracy: 46.2. Result ID: 699488fe3a6c3148491ddbb6.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa69581e209131cea21ad0.md>)

[Implementation](<https://github.com/OpenAI/CLIP>)

Recorded evaluation configuration: {"Pre-training Dataset":"NA (L)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### Moco

Phase Accuracy: 45.4. Result ID: 699488fe3a6c3148491ddbb4.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa673f1e209131cea15344.md>)

[Implementation](<https://github.com/facebookresearch/moco>)

Recorded evaluation configuration: {"Pre-training Dataset":"Cholec80 (V)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### CLIP

Phase Accuracy: 45.3. Result ID: 699488fe3a6c3148491ddbb8.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa69581e209131cea21ad0.md>)

[Implementation](<https://github.com/OpenAI/CLIP>)

Recorded evaluation configuration: {"Pre-training Dataset":"SVL (L)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.

### ImageNet

Phase Accuracy: 44.9. Result ID: 699488fe3a6c3148491ddbb0.

[Reporting paper](<https://www.sota2.com/research/paper/68fa77691e209131cea731fe.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa61b41e209131ce9f58d2.md>)

Recorded evaluation configuration: {"Pre-training Dataset":"ImageNet (V)","%shot":"10","Protocol":"Linear Probing"}. This record does not assert independent reproduction.