# MRI Reconstruction on fastMRI Knee v1.0 (test)

Source: [MRI Reconstruction on fastMRI Knee v1.0 (test)](<https://www.sota2.com/research/sota/mri-reconstruction-on-fastmri-knee-v1-0-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-02-26T06:03:28.579Z

Evaluation of MRI reconstruction performance on the test split of the fastMRI Knee dataset version 1.0, measured using SSIM, QR (%), and ResM (%).

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | MRI Reconstruction |
| Dataset (including any stated split) | fastMRI Knee v1.0 (test) |
| Metric | SSIM |
| Unit | SCALAR |
| Direction | Higher is better |
| Results loaded | 2 of 2 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [SSIM](<https://www.sota2.com/research/sota/mri-reconstruction-on-fastmri-knee-v1-0-test.md?metric=SSIM>): Higher is better; unit: SCALAR.

- [QR (%)](<https://www.sota2.com/research/sota/mri-reconstruction-on-fastmri-knee-v1-0-test.md?metric=QR%20(%25)>): Lower is better; unit: PERCENT.

- [ResM (%)](<https://www.sota2.com/research/sota/mri-reconstruction-on-fastmri-knee-v1-0-test.md?metric=ResM%20(%25)>): Lower is better; unit: PERCENT.

## Recorded results

| Method | SSIM | Result date | Report paper |
| --- | --- | --- | --- |
| E2E VarNet with QR-based uncertainty estimation module | 0.927 | Not recorded | 69705dd7e25ad2fa9d1ed636 |
| E2E VarNet with QR-based uncertainty estimation module | 0.911 | Not recorded | 69705dd7e25ad2fa9d1ed636 |

### E2E VarNet with QR-based uncertainty estimation module

SSIM: 0.927. Result ID: 699a21a25698665ec4a6961b.

[Reporting paper](<https://www.sota2.com/research/paper/69705dd7e25ad2fa9d1ed636.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69705dd7e25ad2fa9d1ed636.md>)

Recorded evaluation configuration: {"Acceleration":"4x"}. This record does not assert independent reproduction.

### E2E VarNet with QR-based uncertainty estimation module

SSIM: 0.911. Result ID: 699a21a25698665ec4a6961c.

[Reporting paper](<https://www.sota2.com/research/paper/69705dd7e25ad2fa9d1ed636.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69705dd7e25ad2fa9d1ed636.md>)

Recorded evaluation configuration: {"Acceleration":"6x"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.