# MRI Enhancement on 3T-to-7T T2 (test)

Source: [MRI Enhancement on 3T-to-7T T2 (test)](<https://www.sota2.com/research/sota/mri-enhancement-on-3t-to-7t-t2-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-11T07:28:10.898Z

Evaluation of MRI Enhancement performance on the 3T-to-7T T2 dataset (test split), assessed using metrics including NRMSE, PSNR, SSIM, and LPIPS.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | MRI Enhancement |
| Dataset (including any stated split) | 3T-to-7T T2 (test) |
| Metric | NRMSE |
| Unit | SCALAR |
| Direction | Lower is better |
| Results loaded | 5 of 5 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [NRMSE](<https://www.sota2.com/research/sota/mri-enhancement-on-3t-to-7t-t2-test.md?metric=NRMSE>): Lower is better; unit: SCALAR.

- [PSNR](<https://www.sota2.com/research/sota/mri-enhancement-on-3t-to-7t-t2-test.md?metric=PSNR>): Higher is better; unit: SCALAR.

- [SSIM](<https://www.sota2.com/research/sota/mri-enhancement-on-3t-to-7t-t2-test.md?metric=SSIM>): Higher is better; unit: PERCENT.

- [LPIPS](<https://www.sota2.com/research/sota/mri-enhancement-on-3t-to-7t-t2-test.md?metric=LPIPS>): Lower is better; unit: SCALAR.

## Recorded results

| Method | NRMSE | Result date | Report paper |
| --- | --- | --- | --- |
| UniField | 7.5 | Not recorded | 69b0f6ff2d603e6de3e45d23 |
| MSFA | 8.1 | Not recorded | 69b0f6ff2d603e6de3e45d23 |
| MO-U-NET | 8.6 | Not recorded | 69b0f6ff2d603e6de3e45d23 |
| FlashVSR | 9.5 | Not recorded | 69b0f6ff2d603e6de3e45d23 |
| LowGAN | 10.1 | Not recorded | 69b0f6ff2d603e6de3e45d23 |

### UniField

NRMSE: 7.5. Result ID: 69b1198a6dbb7075b95b2239.

[Reporting paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### MSFA

NRMSE: 8.1. Result ID: 69b1198a6dbb7075b95b2236.

[Reporting paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa74031e209131cea5f3a1.md>)

Recorded evaluation configuration: {"Year":"2024"}. This record does not assert independent reproduction.

### MO-U-NET

NRMSE: 8.6. Result ID: 69b1198a6dbb7075b95b2235.

[Reporting paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

Recorded evaluation configuration: {"Year":"2025"}. This record does not assert independent reproduction.

### FlashVSR

NRMSE: 9.5. Result ID: 69b1198a6dbb7075b95b2238.

[Reporting paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa7c1c1e209131cea8c683.md>)

[Implementation](<https://github.com/OpenImagingLab/FlashVSR>)

Recorded evaluation configuration: {"Year":"2026"}. This record does not assert independent reproduction.

### LowGAN

NRMSE: 10.1. Result ID: 69b1198a6dbb7075b95b2237.

[Reporting paper](<https://www.sota2.com/research/paper/69b0f6ff2d603e6de3e45d23.md>)

Recorded evaluation configuration: {"Year":"2025"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
