# Lung CT Synthesis on Lung CT (test)

Source: [Lung CT Synthesis on Lung CT (test)](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-25T14:49:49.628Z

Evaluation of models generating synthetic Lung CT images, assessed using precision metrics calculated across specific Hounsfield Unit (HU) density ranges on the test set.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Lung CT Synthesis |
| Dataset (including any stated split) | Lung CT (test) |
| Metric | Precision (Full-range) |
| Unit | SCALAR |
| Direction | Higher is better |
| Results loaded | 13 of 13 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Precision (Full-range)](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test.md?metric=Precision%20(Full-range)>): Higher is better; unit: SCALAR.

- [Precision (\[-950, -700\])](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test.md?metric=Precision%20(%5B-950%2C%20-700%5D)>): Higher is better; unit: SCALAR.

- [Precision (\[-500, -200\])](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test.md?metric=Precision%20(%5B-500%2C%20-200%5D)>): Higher is better; unit: SCALAR.

- [Precision (\[30, 70\])](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test.md?metric=Precision%20(%5B30%2C%2070%5D)>): Higher is better; unit: SCALAR.

- [Precision (\[100, 1000\])](<https://www.sota2.com/research/sota/lung-ct-synthesis-on-lung-ct-test.md?metric=Precision%20(%5B100%2C%201000%5D)>): Higher is better; unit: SCALAR.

## Recorded results

| Method | Precision (Full-range) | Result date | Report paper |
| --- | --- | --- | --- |
| Score-based DM | 0.747 | Not recorded | 69c36c450636e5bf4afc66ed |
| VQVAE | 0.639 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-head VQVAE | 0.576 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-decoder VQVAE | 0.564 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-head VQVAE | 0.454 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-decoder VQVAE | 0.448 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-channel VQVAE | 0.416 | Not recorded | 69c36c450636e5bf4afc66ed |
| multi-channel VQVAE | 0.382 | Not recorded | 69c36c450636e5bf4afc66ed |
| Score-based DM | 0.311 | Not recorded | 69c36c450636e5bf4afc66ed |
| Score-based DM | 0.208 | Not recorded | 69c36c450636e5bf4afc66ed |
| WGAN-GP | 0.022 | Not recorded | 69c36c450636e5bf4afc66ed |
| WGAN-GP | 0.001 | Not recorded | 69c36c450636e5bf4afc66ed |
| WGAN-GP | 0.001 | Not recorded | 69c36c450636e5bf4afc66ed |

### Score-based DM

Precision (Full-range): 0.747. Result ID: 69c3f5fc47f34ce924adeff0.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"Score-based DM","Approach":"Baseline","Reconstruction Model":"-"}. This record does not assert independent reproduction.

### VQVAE

Precision (Full-range): 0.639. Result ID: 69c3f5fc47f34ce924adeff3.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Baseline","Reconstruction Model":"-"}. This record does not assert independent reproduction.

### multi-head VQVAE

Precision (Full-range): 0.576. Result ID: 69c3f5fc47f34ce924adeff9.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-head","Reconstruction Model":"CNN3x3x3"}. This record does not assert independent reproduction.

### multi-decoder VQVAE

Precision (Full-range): 0.564. Result ID: 69c3f5fc47f34ce924adeff7.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-decoder","Reconstruction Model":"CNN3x3x3"}. This record does not assert independent reproduction.

### multi-head VQVAE

Precision (Full-range): 0.454. Result ID: 69c3f5fc47f34ce924adeff8.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-head","Reconstruction Model":"MLP0"}. This record does not assert independent reproduction.

### multi-decoder VQVAE

Precision (Full-range): 0.448. Result ID: 69c3f5fc47f34ce924adeff6.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-decoder","Reconstruction Model":"MLP0"}. This record does not assert independent reproduction.

### multi-channel VQVAE

Precision (Full-range): 0.416. Result ID: 69c3f5fc47f34ce924adeff5.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-channel","Reconstruction Model":"CNN3x3x3"}. This record does not assert independent reproduction.

### multi-channel VQVAE

Precision (Full-range): 0.382. Result ID: 69c3f5fc47f34ce924adeff4.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"VQVAE","Approach":"Multi-channel","Reconstruction Model":"MLP0"}. This record does not assert independent reproduction.

### Score-based DM

Precision (Full-range): 0.311. Result ID: 69c3f5fc47f34ce924adeff1.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"Score-based DM","Approach":"Multi-channel","Reconstruction Model":"MLP0"}. This record does not assert independent reproduction.

### Score-based DM

Precision (Full-range): 0.208. Result ID: 69c3f5fc47f34ce924adeff2.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"Score-based DM","Approach":"Multi-channel","Reconstruction Model":"CNN3x3x3"}. This record does not assert independent reproduction.

### WGAN-GP

Precision (Full-range): 0.022. Result ID: 69c3f5fc47f34ce924adefed.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"WGAN-GP","Approach":"Baseline","Reconstruction Model":"-"}. This record does not assert independent reproduction.

### WGAN-GP

Precision (Full-range): 0.001. Result ID: 69c3f5fc47f34ce924adefee.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"WGAN-GP","Approach":"Multi-channel","Reconstruction Model":"MLP0"}. This record does not assert independent reproduction.

### WGAN-GP

Precision (Full-range): 0.001. Result ID: 69c3f5fc47f34ce924adefef.

[Reporting paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c36c450636e5bf4afc66ed.md>)

Recorded evaluation configuration: {"Model Type":"WGAN-GP","Approach":"Multi-channel","Reconstruction Model":"CNN3x3x3"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
