# Image Classification on Office-Home OOD (test)

Source: [Image Classification on Office-Home OOD (test)](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-06-01T09:14:48.893Z

Evaluation of Image Classification performance on the Out-of-Distribution (OOD) test split of the Office-Home dataset, focusing on generalization metrics.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Image Classification |
| Dataset (including any stated split) | Office-Home OOD (test) |
| Metric | Accuracy (Acc.) |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 5 of 5 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Accuracy (Acc.)](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test.md?metric=Accuracy%20(Acc.)>): Higher is better; unit: PERCENT.

- [Expected Calibration Error (ECE)](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test.md?metric=Expected%20Calibration%20Error%20(ECE)>): Lower is better; unit: SCALAR.

- [Temperature Scaling ECE (TS-ECE)](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test.md?metric=Temperature%20Scaling%20ECE%20(TS-ECE)>): Lower is better; unit: SCALAR.

- [CECE](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test.md?metric=CECE>): Lower is better; unit: SCALAR.

- [Average Calibration Error (ACE)](<https://www.sota2.com/research/sota/image-classification-on-office-home-ood-test.md?metric=Average%20Calibration%20Error%20(ACE)>): Lower is better; unit: SCALAR.

## Recorded results

| Method | Accuracy (Acc.) | Result date | Report paper |
| --- | --- | --- | --- |
| CE | 34.2 | Not recorded | 68fa7af41e209131cea85f3e |
| DFL | 34.17 | Not recorded | 68fa7af41e209131cea85f3e |
| FGR | 34.03 | Not recorded | 68fa7af41e209131cea85f3e |
| FLSD-53 | 33.31 | Not recorded | 68fa7af41e209131cea85f3e |
| BSCE-GRA | 32.55 | Not recorded | 68fa7af41e209131cea85f3e |

### CE

Accuracy (Acc.): 34.2. Result ID: 6a1d4d17fbc373592c16bd76.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

Recorded evaluation configuration: {"Backbone":"ResNet-50","Evaluation Protocol":"leave-one-domain-out"}. This record does not assert independent reproduction.

### DFL

Accuracy (Acc.): 34.17. Result ID: 6a1d4d17fbc373592c16bd78.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa6f681e209131cea45624.md>)

Recorded evaluation configuration: {"Backbone":"ResNet-50","Evaluation Protocol":"leave-one-domain-out"}. This record does not assert independent reproduction.

### FGR

Accuracy (Acc.): 34.03. Result ID: 6a1d4d17fbc373592c16bd7a.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

Recorded evaluation configuration: {"Backbone":"ResNet-50","Evaluation Protocol":"leave-one-domain-out"}. This record does not assert independent reproduction.

### FLSD-53

Accuracy (Acc.): 33.31. Result ID: 6a1d4d17fbc373592c16bd77.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa68a21e209131cea1d496.md>)

Recorded evaluation configuration: {"Backbone":"ResNet-50","Evaluation Protocol":"leave-one-domain-out"}. This record does not assert independent reproduction.

### BSCE-GRA

Accuracy (Acc.): 32.55. Result ID: 6a1d4d17fbc373592c16bd79.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7af41e209131cea85f3e.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa77bd1e209131cea750a1.md>)

[Implementation](<https://github.com/Jinxu-Lin/BSCE-GRA>)

Recorded evaluation configuration: {"Backbone":"ResNet-50","Evaluation Protocol":"leave-one-domain-out"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
