# Image Classification on Acute Lymphoblastic Leukaemia (ALL)

Source: [Image Classification on Acute Lymphoblastic Leukaemia (ALL)](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-13T07:48:16.405Z

Evaluation of Image Classification performance on the Acute Lymphoblastic Leukaemia (ALL) dataset, reporting standard metrics such as Accuracy, Precision, Recall, F1-Score, and ROC-AUC.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Image Classification |
| Dataset (including any stated split) | Acute Lymphoblastic Leukaemia (ALL) |
| Metric | Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 4 of 4 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Accuracy](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all.md?metric=Accuracy>): Higher is better; unit: PERCENT.

- [Precision](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all.md?metric=Precision>): Higher is better; unit: PERCENT.

- [Recall](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all.md?metric=Recall>): Higher is better; unit: PERCENT.

- [F1-Score](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all.md?metric=F1-Score>): Higher is better; unit: PERCENT.

- [ROC-AUC](<https://www.sota2.com/research/sota/image-classification-on-acute-lymphoblastic-leukaemia-all.md?metric=ROC-AUC>): Higher is better; unit: PERCENT.

## Recorded results

| Method | Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| DeepHistoViT | 99.85 | Not recorded | 69b399e80636e5bf4afbc8d0 |
| ALL-Net | 99.32 | Not recorded | 69b399e80636e5bf4afbc8d0 |
| DarkNet19 ESA | 98.52 | Not recorded | 69b399e80636e5bf4afbc8d0 |
| EfficientNet-B7 | 96.78 | Not recorded | 69b399e80636e5bf4afbc8d0 |

### DeepHistoViT

Accuracy: 99.85. Result ID: 69b3c07a47f34ce9249d7d59.

[Reporting paper](<https://www.sota2.com/research/paper/69b399e80636e5bf4afbc8d0.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69b399e80636e5bf4afbc8d0.md>)

Recorded evaluation configuration: {"Study":"Proposed"}. This record does not assert independent reproduction.

### ALL-Net

Accuracy: 99.32. Result ID: 69b3c07a47f34ce9249d7d58.

[Reporting paper](<https://www.sota2.com/research/paper/69b399e80636e5bf4afbc8d0.md>)

Recorded evaluation configuration: {"Study":"Thiriveedhi et al. (2025)"}. This record does not assert independent reproduction.

### DarkNet19 ESA

Accuracy: 98.52. Result ID: 69b3c07a47f34ce9249d7d57.

[Reporting paper](<https://www.sota2.com/research/paper/69b399e80636e5bf4afbc8d0.md>)

Recorded evaluation configuration: {"Study":"Basaran et al. (2025)"}. This record does not assert independent reproduction.

### EfficientNet-B7

Accuracy: 96.78. Result ID: 69b3c07a47f34ce9249d7d56.

[Reporting paper](<https://www.sota2.com/research/paper/69b399e80636e5bf4afbc8d0.md>)

Recorded evaluation configuration: {"Study":"Muhammad et al. (2025)"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
