# Gaze Direction Verification on MPIIFaceGaze

Source: [Gaze Direction Verification on MPIIFaceGaze](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-20T07:03:28.495Z

Evaluation of Gaze Direction Verification performance on the MPIIFaceGaze dataset, utilizing classification metrics like TP, TN, FP, FN, and MCC.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Gaze Direction Verification |
| Dataset (including any stated split) | MPIIFaceGaze |
| Metric | True Positives (TP) |
| Unit | SCALAR |
| Direction | Higher is better |
| Results loaded | 2 of 2 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [True Positives (TP)](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze.md?metric=True%20Positives%20(TP)>): Higher is better; unit: SCALAR.

- [True Negatives (TN)](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze.md?metric=True%20Negatives%20(TN)>): Higher is better; unit: SCALAR.

- [False Positives (FP)](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze.md?metric=False%20Positives%20(FP)>): Lower is better; unit: SCALAR.

- [False Negatives (FN)](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze.md?metric=False%20Negatives%20(FN)>): Lower is better; unit: SCALAR.

- [MCC](<https://www.sota2.com/research/sota/gaze-direction-verification-on-mpiifacegaze.md?metric=MCC>): Higher is better; unit: SCALAR.

## Recorded results

| Method | True Positives (TP) | Result date | Report paper |
| --- | --- | --- | --- |
| QualitEye | 0.9628 | Not recorded | 68fa792d1e209131cea7c6b6 |
| QualitEye | 0.8381 | Not recorded | 68fa792d1e209131cea7c6b6 |

### QualitEye

True Positives (TP): 0.9628. Result ID: 69bcf13747f34ce924a6b1ba.

[Reporting paper](<https://www.sota2.com/research/paper/68fa792d1e209131cea7c6b6.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa792d1e209131cea7c6b6.md>)

Recorded evaluation configuration: {"evaluation\_mode":"Within-dataset performance","aggregation":"averaged over different participant-based data splits"}. This record does not assert independent reproduction.

### QualitEye

True Positives (TP): 0.8381. Result ID: 69bcf13747f34ce924a6b1bc.

[Reporting paper](<https://www.sota2.com/research/paper/68fa792d1e209131cea7c6b6.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa792d1e209131cea7c6b6.md>)

Recorded evaluation configuration: {"evaluation\_mode":"Within-dataset performance","aggregation":"averaged over different participant-based data splits"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.