# ECG Classification on PhysioNet MIT-BIH Arrhythmia Dataset (test)

Source: [ECG Classification on PhysioNet MIT-BIH Arrhythmia Dataset (test)](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-04T08:55:03.407Z

Evaluation of ECG Classification performance on the test split of the PhysioNet MIT-BIH Arrhythmia Dataset, reporting Accuracy, Precision, Recall, and F1-score.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | ECG Classification |
| Dataset (including any stated split) | PhysioNet MIT-BIH Arrhythmia Dataset (test) |
| Metric | Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 3 of 3 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Accuracy](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test.md?metric=Accuracy>): Higher is better; unit: PERCENT.

- [Precision](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test.md?metric=Precision>): Higher is better; unit: PERCENT.

- [Recall](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test.md?metric=Recall>): Higher is better; unit: PERCENT.

- [F1-score](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test.md?metric=F1-score>): Higher is better; unit: PERCENT.

## Recorded results

| Method | Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| RC-GRU | 94.1 | Not recorded | 69a66bdb2d603e6de3e3cc7a |
| GRU | 92.1 | Not recorded | 69a66bdb2d603e6de3e3cc7a |
| LSTM | 91.3 | Not recorded | 69a66bdb2d603e6de3e3cc7a |

### RC-GRU

Accuracy: 94.1. Result ID: 69a7f35c6dbb7075b94ceb78.

[Reporting paper](<https://www.sota2.com/research/paper/69a66bdb2d603e6de3e3cc7a.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69a66bdb2d603e6de3e3cc7a.md>)

Recorded evaluation configuration: {"Framework":"RC-GRF","Hidden units":"128","Optimizer":"Adam","Learning rate":"0.001","Batch size":"64"}. This record does not assert independent reproduction.

### GRU

Accuracy: 92.1. Result ID: 69a7f35c6dbb7075b94ceb77.

[Reporting paper](<https://www.sota2.com/research/paper/69a66bdb2d603e6de3e3cc7a.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa617f1e209131ce9f4955.md>)

Recorded evaluation configuration: {"Hidden units":"128","Optimizer":"Adam","Learning rate":"0.001","Batch size":"64"}. This record does not assert independent reproduction.

### LSTM

Accuracy: 91.3. Result ID: 69a7f35c6dbb7075b94ceb76.

[Reporting paper](<https://www.sota2.com/research/paper/69a66bdb2d603e6de3e3cc7a.md>)

Recorded evaluation configuration: {"Hidden units":"128","Optimizer":"Adam","Learning rate":"0.001","Batch size":"64"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.