# Audio Classification on AudioMNIST 40-150-10 (test)

Source: [Audio Classification on AudioMNIST 40-150-10 (test)](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-06-23T07:44:14.062Z

Evaluation of Audio Classification performance on the specific AudioMNIST 40-150-10 test split, reporting both standard accuracy metrics and hardware resource utilization (LUTs, FFs, BRAMs, Power, Latency).

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Audio Classification |
| Dataset (including any stated split) | AudioMNIST 40-150-10 (test) |
| Metric | Reference Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 2 of 2 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Reference Accuracy](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=Reference%20Accuracy>): Higher is better; unit: PERCENT.

- [Hardware Accuracy](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=Hardware%20Accuracy>): Higher is better; unit: PERCENT.

- [LUT Count](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=LUT%20Count>): Lower is better; unit: SIZE.

- [FF Count](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=FF%20Count>): Lower is better; unit: SIZE.

- [DSP Count](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=DSP%20Count>): Lower is better; unit: SIZE.

- [BRAM Count](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=BRAM%20Count>): Lower is better; unit: SIZE.

- [Power (mW)](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=Power%20(mW)>): Lower is better; unit: OTHER.

- [Latency (ms)](<https://www.sota2.com/research/sota/audio-classification-on-audiomnist-40-150-10-test.md?metric=Latency%20(ms)>): Lower is better; unit: TIME.

## Recorded results

| Method | Reference Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| Spiker+ | 95.23 | Not recorded | 6a3a1306206542251d7c6f00 |
| VQ4SNN | 93.12 | Not recorded | 6a3a1306206542251d7c6f00 |

### Spiker+

Reference Accuracy: 95.23. Result ID: 6a3a390ffbc373592c342946.

[Reporting paper](<https://www.sota2.com/research/paper/6a3a1306206542251d7c6f00.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa764b1e209131cea6c2fb.md>)

Recorded evaluation configuration: {"Design":"Spiker+","Network Type":"FC-FF-R","Weight bits":"5","Memb. Potential bits":"8","Spikes time-steps":"73"}. This record does not assert independent reproduction.

### VQ4SNN

Reference Accuracy: 93.12. Result ID: 6a3a390ffbc373592c342947.

[Reporting paper](<https://www.sota2.com/research/paper/6a3a1306206542251d7c6f00.md>)

[Method origin paper](<https://www.sota2.com/research/paper/6a3a1306206542251d7c6f00.md>)

Recorded evaluation configuration: {"Design":"Proposed","Config":"L1:d=4 k=2^10","Network Type":"FC-FF","Weight bits":"6","Memb. Potential bits":"12","Spikes time-steps":"100"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
