# Appliance State Recognition on Laboratory Dataset Real Injection

Source: [Appliance State Recognition on Laboratory Dataset Real Injection](<https://www.sota2.com/research/sota/appliance-state-recognition-on-laboratory-dataset-real-injection>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-06-23T10:18:26.323Z

Evaluation of model performance on Appliance State Recognition using the Laboratory Dataset Real Injection, reporting Accuracy, Recall, Precision, and F1 scores.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Appliance State Recognition |
| Dataset (including any stated split) | Laboratory Dataset Real Injection |
| Metric | Accuracy |
| Unit | PERCENT |
| Direction | Higher is better |
| Results loaded | 7 of 7 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Accuracy](<https://www.sota2.com/research/sota/appliance-state-recognition-on-laboratory-dataset-real-injection.md?metric=Accuracy>): Higher is better; unit: PERCENT.

- [Recall](<https://www.sota2.com/research/sota/appliance-state-recognition-on-laboratory-dataset-real-injection.md?metric=Recall>): Higher is better; unit: PERCENT.

- [Precision](<https://www.sota2.com/research/sota/appliance-state-recognition-on-laboratory-dataset-real-injection.md?metric=Precision>): Higher is better; unit: PERCENT.

- [F1 Score](<https://www.sota2.com/research/sota/appliance-state-recognition-on-laboratory-dataset-real-injection.md?metric=F1%20Score>): Higher is better; unit: PERCENT.

## Recorded results

| Method | Accuracy | Result date | Report paper |
| --- | --- | --- | --- |
| DualNILM | 98.54 | Not recorded | 68fa7ba71e209131cea89aa7 |
| UNetNILM | 89.2 | Not recorded | 68fa7ba71e209131cea89aa7 |
| XGBoost | 85.82 | Not recorded | 68fa7ba71e209131cea89aa7 |
| Transformer | 81.79 | Not recorded | 68fa7ba71e209131cea89aa7 |
| CNN-LSTM | 74.03 | Not recorded | 68fa7ba71e209131cea89aa7 |
| Seq2Point | 67.63 | Not recorded | 68fa7ba71e209131cea89aa7 |
| FHMM | 60.95 | Not recorded | 68fa7ba71e209131cea89aa7 |

### DualNILM

Accuracy: 98.54. Result ID: 6a3a5d60fbc373592c36a2f9.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### UNetNILM

Accuracy: 89.2. Result ID: 6a3a5d60fbc373592c36a2f8.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### XGBoost

Accuracy: 85.82. Result ID: 6a3a5d60fbc373592c36a2f4.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa62821e209131ce9f9b56.md>)

[Implementation](<https://github.com/dmlc/xgboost>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### Transformer

Accuracy: 81.79. Result ID: 6a3a5d60fbc373592c36a2f7.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa703d1e209131cea49db1.md>)

[Implementation](<https://github.com/tensorflow/tensor2tensor>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### CNN-LSTM

Accuracy: 74.03. Result ID: 6a3a5d60fbc373592c36a2f6.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### Seq2Point

Accuracy: 67.63. Result ID: 6a3a5d60fbc373592c36a2f5.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa63f61e209131cea01dd2.md>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

### FHMM

Accuracy: 60.95. Result ID: 6a3a5d60fbc373592c36a2f3.

[Reporting paper](<https://www.sota2.com/research/paper/68fa7ba71e209131cea89aa7.md>)

Recorded evaluation configuration: {"Evaluation protocol":"Cross-validation"}. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.
