# Analog circuit design optimization on 130nm 12 Params Circuit

Source: [Analog circuit design optimization on 130nm 12 Params Circuit](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-27T12:28:22.713Z

Evaluation of analog circuit design optimization algorithms on the '130nm 12 Params Circuit' configuration, measuring performance metrics such as Gain, UGBW, Power, Figure of Merit (FoM), and feasibility rates.

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

| Scope | Recorded value |
| --- | --- |
| Task | Analog circuit design optimization |
| Dataset (including any stated split) | 130nm 12 Params Circuit |
| Metric | Gain (dB) |
| Unit | SCALAR |
| Direction | Higher is better |
| Results loaded | 5 of 5 |
| Coverage | All results currently returned for this benchmark |

Evaluation settings may differ between results. The original papers and recorded configurations are needed to establish comparability. A shared metric name alone does not establish an identical protocol.

## Metrics

- [Gain (dB)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Gain%20(dB)>): Higher is better; unit: SCALAR.

- [UGBW (MHz)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=UGBW%20(MHz)>): Higher is better; unit: SCALAR.

- [Phase Margin (deg)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Phase%20Margin%20(deg)>): Higher is better; unit: SCALAR.

- [Power (mW)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Power%20(mW)>): Lower is better; unit: SIZE.

- [FoM](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=FoM>): Higher is better; unit: SCALAR.

- [Simulation Validity (%)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Simulation%20Validity%20(%25)>): Higher is better; unit: PERCENT.

- [Physical Feasibility (%)](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Physical%20Feasibility%20(%25)>): Higher is better; unit: PERCENT.

- [Number of Regions](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Number%20of%20Regions>): Higher is better; unit: SCALAR.

- [Optimization Regret](<https://www.sota2.com/research/sota/analog-circuit-design-optimization-on-130nm-12-params-circuit.md?metric=Optimization%20Regret>): Lower is better; unit: SCALAR.

## Recorded results

| Method | Gain (dB) | Result date | Report paper |
| --- | --- | --- | --- |
| Target Spec. | 85 | Not recorded | 69c60f190636e5bf4afc8594 |
| ACOF | 83.65 | Not recorded | 69c60f190636e5bf4afc8594 |
| Single-LLM | 83.15 | Not recorded | 69c60f190636e5bf4afc8594 |
| Pure-BO | 76.24 | Not recorded | 69c60f190636e5bf4afc8594 |
| Human Expert | 72.77 | Not recorded | 69c60f190636e5bf4afc8594 |

### Target Spec.

Gain (dB): 85. Result ID: 69c676d447f34ce924b03c92.

[Reporting paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### ACOF

Gain (dB): 83.65. Result ID: 69c676d447f34ce924b03c93.

[Reporting paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

[Method origin paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

Recorded evaluation configuration: {"LLM":"Qwen"}. This record does not assert independent reproduction.

### Single-LLM

Gain (dB): 83.15. Result ID: 69c676d447f34ce924b03c94.

[Reporting paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

[Method origin paper](<https://www.sota2.com/research/paper/68fa79311e209131cea7c8aa.md>)

Recorded evaluation configuration: {"LLM":"Qwen"}. This record does not assert independent reproduction.

### Pure-BO

Gain (dB): 76.24. Result ID: 69c676d447f34ce924b03c95.

[Reporting paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

### Human Expert

Gain (dB): 72.77. Result ID: 69c676d447f34ce924b03c96.

[Reporting paper](<https://www.sota2.com/research/paper/69c60f190636e5bf4afc8594.md>)

Recorded evaluation configuration: Not recorded. This record does not assert independent reproduction.

Page 1 of 1. This is an index page, not the full collection.