# Active Diffusion Matching: Score-based Iterative Alignment of Cross-Modal Retinal Images

Source: [Active Diffusion Matching: Score-based Iterative Alignment of Cross-Modal Retinal Images](<https://www.sota2.com/research/paper/69ddc9f07d0172140ec79895>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-04-15T05:00:04.591Z

Authors: Kanggeon Lee, Su Jeong Song, Soochahn Lee, Kyoung Mu Lee

Published: 2026-04-11T08:06:28.000Z

## Abstract

Objective: The study aims to address the challenge of aligning Standard Fundus Images (SFIs) and Ultra-Widefield Fundus Images (UWFIs), which is difficult due to their substantial differences in viewing range and the amorphous appearance of the retina. Currently, no specialized method exists for this task, and existing image alignment techniques lack accuracy.   Methods: We propose Active Diffusion Matching (ADM), a novel cross-modal alignment method. ADM integrates two interdependent score-based diffusion models to jointly estimate global transformations and local deformations via an iterative Langevin Markov chain. This approach facilitates a stochastic, progressive search for optimal alignment. Additionally, custom sampling strategies are introduced to enhance the adaptability of ADM to given input image pairs.   Results: Comparative experimental evaluations demonstrate that ADM achieves state-of-the-art alignment accuracy. This was validated on two datasets: a private dataset of SFI-UWFI pairs and a public dataset of SFI-SFI pairs, with mAUC improvements of 5.2 and 0.4 points on the private and public datasets, respectively, compared to existing state-of-the-art methods.   Conclusion: ADM effectively bridges the gap in aligning SFIs and UWFIs, providing an innovative solution to a previously unaddressed challenge. The method's ability to jointly optimize global and local alignment makes it highly effective for cross-modal image alignment tasks.   Significance: ADM has the potential to transform the integrated analysis of SFIs and UWFIs, enabling better clinical utility and supporting learning-based image enhancements. This advancement could significantly improve diagnostic accuracy and patient outcomes in ophthalmology.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Retinal Image Alignment on FIRE](<https://www.sota2.com/research/sota/retinal-image-alignment-on-fire.md>): Retinal Image Alignment; FIRE; Acceptable Success Rate: 98.51.

- [Homography Estimation on KBSMC](<https://www.sota2.com/research/sota/homography-estimation-on-kbsmc.md>): Homography Estimation; KBSMC; Success Rate (Failed): 0.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2604.10084>)

[PDF](<https://arxiv.org/pdf/2604.10084.pdf>)
