# Deep Learning Based Estimation of Blood Glucose Levels from Multidirectional Scleral Blood Vessel Imaging

Source: [Deep Learning Based Estimation of Blood Glucose Levels from Multidirectional Scleral Blood Vessel Imaging](<https://www.sota2.com/research/paper/69b78e630636e5bf4afbda7f>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-17T05:00:04.157Z

Authors: Muhammad Ahmed Khan, Manqiang Peng, Ding Lin, Saif Ur Rehman Khan

Published: 2026-03-13T07:01:19.000Z

## Abstract

Regular monitoring of glycemic status is essential for diabetes management, yet conventional blood-based testing can be burdensome for frequent assessment. The sclera contains superficial microvasculature that may exhibit diabetes related alterations and is readily visible on the ocular surface. We propose ScleraGluNet, a multiview deep-learning framework for three-class metabolic status classification (normal, controlled diabetes, and high-glucose diabetes) and continuous fasting plasma glucose (FPG) estimation from multidirectional scleral vessel images. The dataset comprised 445 participants (150/140/155) and 2,225 anterior-segment images acquired from five gaze directions per participant. After vascular enhancement, features were extracted using parallel convolutional branches, refined with Manta Ray Foraging Optimization (MRFO), and fused via transformer-based cross-view attention. Performance was evaluated using subject-wise five-fold cross-validation, with all images from each participant assigned to the same fold. ScleraGluNet achieved 93.8% overall accuracy, with one-vs-rest AUCs of 0.971,0.956, and 0.982 for normal, controlled diabetes, and high-glucose diabetes, respectively. For FPG estimation, the model achieved MAE = 6.42 mg/dL and RMSE = 7.91 mg/dL, with strong correlation to laboratory measurements (r = 0.983; R2 = 0.966). Bland Altman analysis showed a mean bias of +1.45 mg/dL with 95% limits of agreement from -8.33 to +11.23$ mg/dL. These results support multidirectional scleral vessel imaging with multiview learning as a promising noninvasive approach for glycemic assessment, warranting multicenter validation before clinical deployment.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Multiclass metabolic status classification on Metabolic Status Classification Dataset (5-fold CV subject-level evaluation)](<https://www.sota2.com/research/sota/multiclass-metabolic-status-classification-on-metabolic-status-classification-dataset-5-fold-cv-subject-level-evaluation.md>): Multiclass metabolic status classification; Metabolic Status Classification Dataset 5-fold cross-validation subject-level evaluation; Precision: 94.8.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2603.12715>)