# Pre-Clinical Latency Characterization of VRxBioRelax: A Real-Time EMG Biofeedback System for Muscle Relaxation in Virtual Reality

Source: [Pre-Clinical Latency Characterization of VRxBioRelax: A Real-Time EMG Biofeedback System for Muscle Relaxation in Virtual Reality](<https://www.sota2.com/research/paper/69afa5a42d603e6de3e43c95>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-11T05:00:04.181Z

Authors: Melanie Baumgartner, Raphael Weibel, Tobias Hoesli, Aydin Javadov, Rayna Ney, Helen Schwerdt, Florian von Wangenheim, Joseph Ollier

Published: 2026-03-07T21:37:41.000Z

## Abstract

Chronic tension in the upper trapezius (UT), often caused by poor ergonomics, prolonged posture, or psychological stress, contributes to musculoskeletal discomfort, headaches, and impaired interoceptive awareness. Although surface electromyography (sEMG) biofeedback can promote UT relaxation, traditional systems using conventional displays often fail to sustain engagement. Virtual reality (VR) offers a more immersive alternative, provided that latency remains below perceptual thresholds. We introduce VRxBioRelax, a closed-loop VR biofeedback system that streams sEMG data from Delsys Trigno Avanti sensors via MQTT to a Unity scene. Muscle activation drives a dynamic dawn-to-dusk landscape synchronized with a progressive muscle relaxation protocol. To validate system responsiveness, 87,716 EMG samples from the NinaPro DB2 dataset were replayed at $\\sim$75 Hz. Timestamps at four key stages-acquisition, Root Mean Square (RMS) processing, network receipt, and rendering-revealed mean latencies of 0.50 ms (processing), 5.62 ms (network), and 19.22 ms (rendering), yielding an average end-to-end delay of 25.34 ms. Notably, 99.3% of frames arrived within 50 ms. One-sided t-tests confirmed mean latency was significantly lower than both the 30 ms VR comfort limit ($t\_{87\\,715}=-25.2$, $p=5.9{\\times}10^{-140}$) and the 50 ms clinical benchmark ($t\_{87\\,715}=-133.3$, $p\<10^{-300}$). These findings support VRxBioRelax for use in remote interoceptive training, stress reduction, and telepresence-enabled rehabilitation.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Latency Measurement on VRxBioRelax pipeline latency dataset](<https://www.sota2.com/research/sota/latency-measurement-on-vrxbiorelax-pipeline-latency-dataset.md>): Latency Measurement; VRxBioRelax pipeline latency dataset; Mean Latency (ms): 0.5.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2603.07353>)

[PDF](<https://arxiv.org/pdf/2603.07353.pdf>)