# A Representation-Consistent Gated Recurrent Framework for Robust Medical Time-Series Classification

Source: [A Representation-Consistent Gated Recurrent Framework for Robust Medical Time-Series Classification](<https://www.sota2.com/research/paper/69a66bdb2d603e6de3e3cc7a>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-03-04T05:00:05.078Z

Authors: Maitri Krishna Sai

Published: 2026-02-10T17:16:49.000Z

## Abstract

Medical time-series data are characterized by irregular sampling, high noise levels, missing values, and strong inter-feature dependencies. Recurrent neural networks (RNNs), particularly gated architectures such as Long Short-Term Memory (LSTM) and Gated Recurrent Units (GRU), are widely used for modeling such data due to their ability to capture temporal dependencies. However, standard gated recurrent models do not explicitly constrain the evolution of latent representations over time, leading to representation drift and instability under noisy or incomplete inputs. In this work, we propose a representation-consistent gated recurrent framework (RC-GRF) that introduces a principled regularization strategy to enforce temporal consistency in hidden-state representations. The proposed framework is model-agnostic and can be integrated into existing gated recurrent architectures without modifying their internal gating mechanisms. We provide a theoretical analysis demonstrating how the consistency constraint bounds hidden-state divergence and improves stability. Extensive experiments on medical time-series classification benchmarks show that the proposed approach improves robustness, reduces variance, and enhances generalization performance, particularly in noisy and low-sample settings.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [ECG Classification on PhysioNet MIT-BIH Arrhythmia Dataset (test)](<https://www.sota2.com/research/sota/ecg-classification-on-physionet-mit-bih-arrhythmia-dataset-test.md>): ECG Classification; PhysioNet MIT-BIH Arrhythmia Dataset (test); Accuracy: 94.1.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2603.00067>)

[PDF](<https://arxiv.org/pdf/2603.00067.pdf>)
