## Abstract

Accurate gas temperature ($T\_{\\rm Gas}$) determination in microplasmas is critical for optimizing their applications, yet isolated diagnostic approaches may yield misleading results, especially under strong non-equilibrium conditions. Here, high resolution rotational spectra of N$\_2$(C), OH(A), NH(A) and NO(A), generated in the plasma jet of a DC Ar/N$\_2$ microhollow cathode discharge (MHCD), are recorded and their associated rotational temperatures ($T\_{\\rm rot}$) are cross compared. A detailed experimental analysis and robust fitting of the rotational spectra are performed, achieving a reliable estimation of $T\_{\\rm Gas}$. The dominant formation mechanisms of these species and their corresponding impact on rotational population distributions are also interrogated. Particularly, our findings indicate that the $T\_{\\rm rot}$of N$\_2$(C) is significantly influenced by energy transfers from argon metastables (Ar$^m$) and spectral interference from NH(A). This makes it unreliable as a thermometric probe in Ar-rich MHCD, unless complex analyses are employed. In contrast, OH(A) rotational population distribution appears to be less sensitive to Ar-induced perturbations across various discharge currents and pressures, providing more straightforward results. For all molecules considered, this study reveals the conditions under which all the measured $T\_{\\rm rot}$ can be reliably considered to be in equilibrium with $T\_{\\rm Gas}$. This highlights the importance of crossvalidating multiple thermometric probes and investigating relevant excitation kinetics when measuring $T\_{\\rm rot}$ in reactive microplasmas.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2601.04967>)

[PDF](<https://arxiv.org/pdf/2601.04967.pdf>)