# Real-Time Control and Automation Framework for Acousto-Holographic Microscopy

Source: [Real-Time Control and Automation Framework for Acousto-Holographic Microscopy](<https://www.sota2.com/research/paper/69311570d6b0dd3342933a58>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-12-05T05:03:13.504Z

Authors: Hasan Berkay Abdio\\u{g}lu, Ya\\u{g}mur I\\c{s}{\\i}k, Mustafa \\.Ismail \\.Inal, Nehir Serin, Kerem Bayer, Muhammed Furkan Ko\\c{s}ar, Taha \\"Unal, H\\"useyin \\"Uvet

Published: 2025-12-03T08:00:10.000Z

## Abstract

Manual operation of microscopes for repetitive tasks in cell biology is a significant bottleneck, consuming invaluable expert time, and introducing human error. Automation is essential, and while Digital Holographic Microscopy (DHM) offers powerful, label-free quantitative phase imaging (QPI), its inherently noisy and low-contrast holograms make robust autofocus and object detection challenging. We present the design, integration, and validation of a fully automated closed-loop DHM system engineered for high-throughput mechanical characterization of biological cells. The system integrates automated serpentine scanning, real-time YOLO-based object detection, and a high-performance, multi-threaded software architecture using pinned memory and SPSC queues. This design enables the GPU-accelerated reconstruction pipeline to run fully in parallel with the 50 fps data acquisition, adding no sequential overhead. A key contribution is the validation of a robust, multi-stage holographic autofocus strategy; we demonstrate that a selected metric (based on a low-pass filter and standard deviation) provides reliable focusing for noisy holograms where conventional methods (e.g., Tenengrad, Laplacian) fail entirely. Performance analysis of the complete system identifies the 2.23-second autofocus operation-not reconstruction-as the primary throughput bottleneck, resulting in a 9.62-second analysis time per object. This work delivers a complete functional platform for autonomous DHM screening and provides a clear, data-driven path for future optimization, proposing a hybrid brightfield imaging modality to address current bottlenecks.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2512.03539>)

[PDF](<https://arxiv.org/pdf/2512.03539.pdf>)