# Lorentzian Switching Dynamics in HZO-based FeMEMS Synapses for Neuromorphic Weight Storage

Source: [Lorentzian Switching Dynamics in HZO-based FeMEMS Synapses for Neuromorphic Weight Storage](<https://www.sota2.com/research/paper/690836f73ef7ccd74e5e5459>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-04-18T05:00:12.127Z

Authors: Shubham Jadhav, Kaustav Roy, Luis Amaro, Thejas Basavarajappa, Madhav Ramesh, Debdeep Jena, Huili (Grace) Xing, Amit Lal

Published: 2025-10-31T01:31:58.000Z

## Abstract

Neuromorphic computing demands synaptic elements that can store and update weights with high precision while being read non-destructively. Conventional ferroelectric synapses store weights in remnant polarization states and might require destructive electrical readout, limiting endurance and reliability. We demonstrate a ferroelectric MEMS (FeMEMS) based synapse in which analog weights are stored in the piezoelectric coefficient $d\_{31,eff}$ of a released Hf$\_{0.5}$Zr$\_{0.5}$O$\_2$ (HZO) MEMS unimorph. Partial switching of ferroelectric domains modulates $d\_{31,eff}$, and a low-amplitude mechanical drive reads out the weight without read-disturb in the device yielding more than 7-bit of programming levels. The mechanical switching distribution function follows a Lorentzian distribution as a logarithmic function of partial poling voltage ($V\_p$) consistent with nucleation-limited switching (NLS), and the median threshold extracted from electromechanical data obeys a Merz-type field-time law with a dimensionless exponent $\\alpha = 3.62$. These relationships establish a quantitative link between mechanical weights and electrical switching kinetics. This mechanically read synapse avoids depolarization and charge-injection effects, provides bipolar weights (well suited for excitatory and inhibitory synapses), directly reveals partial domain populations, and offers a robust, energy-efficient route toward high-bit neuromorphic hardware.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2510.27095>)

[PDF](<https://arxiv.org/pdf/2510.27095.pdf>)