# Monitoring of water sorption and swelling of potato starch-glycerol extruded blend by magnetic resonance imaging and multivariate curve resolution

Source: [Monitoring of water sorption and swelling of potato starch-glycerol extruded blend by magnetic resonance imaging and multivariate curve resolution](<https://www.sota2.com/research/paper/68fa80241e209131cea9c171>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-26T06:56:30.471Z

Authors: S\\'ilvia Mas Garcia, Jean-Michel Roger, Ruzica Ferbus, Denis Lourdin, Corinne C. Rondeau-Mouro

Published: 2024-09-02T07:52:46.000Z

## Abstract

Magnetic resonance microimaging (MR mu I) is an outstanding technique for studying water transfers in millimetric bio-based materials in a non-destructive and non-invasive manner. However, depending on the composition of the material, monitoring and quantification of these transfers can be very complex, and hence reliable image processing and analysis tools are necessary. In this study, a combination of MR mu I and multivariate curve resolution-alternating least squares (MCR-ALS) is proposed to monitor the water ingress into a potato starch extruded blend containing 20% glycerol that was shown to have interesting properties for biomedical, textile, and food applications. In this work, the main purpose of MCR is to provide spectral signatures and distribution maps of the components involved in the water uptake process that occurs over time with various kinetics. This approach allowed the description of the system evolution at a global (image) and a local (pixel) level, hence, permitted the resolution of two waterfronts, at two different times into the blend that could not be resolved by any other mathematical processing method usually used in magnetic resonance imaging (MRI). The results were supplemented by scanning electron microscopy (SEM) observations in order to interpret these two waterfronts in a biological and physico-chemical point of view.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2409.01018>)

[PDF](<https://arxiv.org/pdf/2409.01018.pdf>)
