# Synthesizing Late-Stage Contrast Enhancement in Breast MRI: A Comprehensive Pipeline Leveraging Temporal Contrast Enhancement Dynamics

Source: [Synthesizing Late-Stage Contrast Enhancement in Breast MRI: A Comprehensive Pipeline Leveraging Temporal Contrast Enhancement Dynamics](<https://www.sota2.com/research/paper/68fa76b91e209131cea6ebda>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-26T04:01:17.446Z

Authors: Ruben D. Fonnegra, Maria Liliana Hern\\'andez, Juan C. Caicedo, Gloria M. D\\'iaz

Published: 2024-09-03T04:31:49.000Z

## Abstract

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer diagnosis due to its ability to characterize tissue through contrast agent kinetics. However, traditional DCE-MRI protocols require multiple imaging phases, including early and late post-contrast acquisitions, leading to prolonged scan times, patient discomfort, motion artifacts, high costs, and limited accessibility. To overcome these limitations, this study presents a pipeline for synthesizing late-phase DCE-MRI images from early-phase data, replicating the time-intensity (TI) curve behavior in enhanced regions while maintaining visual fidelity across the entire image. The proposed approach introduces a novel loss function, Time Intensity Loss (TI-loss), leveraging the temporal behavior of contrast agents to guide the training of a generative model. Additionally, a new normalization strategy, TI-norm, preserves the contrast enhancement pattern across multiple image sequences at various timestamps, addressing limitations of conventional normalization methods. Two metrics are proposed to evaluate image quality: the Contrast Agent Pattern Score ($\\mathcal{CP}\_{s}$), which validates enhancement patterns in annotated regions, and the Average Difference in Enhancement ($\\mathcal{ED}$), measuring differences between real and generated enhancements. Using a public DCE-MRI dataset with 1.5T and 3T scanners, the proposed method demonstrates accurate synthesis of late-phase images that outperform existing models in replicating the TI curve's behavior in regions of interest while preserving overall image quality. This advancement shows a potential to optimize DCE-MRI protocols by reducing scanning time without compromising diagnostic accuracy, and bringing generative models closer to practical implementation in clinical scenarios to enhance efficiency in breast cancer imaging.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2409.01596>)

[PDF](<https://arxiv.org/pdf/2409.01596.pdf>)
