# APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy

Source: [APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy](<https://www.sota2.com/research/paper/68fa742c1e209131cea6030e>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2026-01-02T06:56:39.069Z

Authors: Yi Sheng, Hanchen Wang, Yipei Liu, Junhuan Yang, Weiwen Jiang, Youzuo Lin, Lei Yang

Published: 2024-07-18T20:30:41.000Z

## Abstract

Ultrasound computed tomography (USCT) is a promising technique that achieves superior medical imaging reconstruction resolution by fully leveraging waveform information, outperforming conventional ultrasound methods. Despite its advantages, high-quality USCT reconstruction relies on extensive data acquisition by a large number of transducers, leading to increased costs, computational demands, extended patient scanning times, and manufacturing complexities. To mitigate these issues, we propose a new USCT method called APS-USCT, which facilitates imaging with sparse data, substantially reducing dependence on high-cost dense data acquisition. Our APS-USCT method consists of two primary components: APS-wave and APS-FWI. The APS-wave component, an encoder-decoder system, preprocesses the waveform data, converting sparse data into dense waveforms to augment sample density prior to reconstruction. The APS-FWI component, utilizing the InversionNet, directly reconstructs the speed of sound (SOS) from the ultrasound waveform data. We further improve the model's performance by incorporating Squeeze-and-Excitation (SE) Blocks and source encoding techniques. Testing our method on a breast cancer dataset yielded promising results. It demonstrated outstanding performance with an average Structural Similarity Index (SSIM) of 0.8431. Notably, over 82% of samples achieved an SSIM above 0.8, with nearly 61% exceeding 0.85, highlighting the significant potential of our approach in improving USCT image reconstruction by efficiently utilizing sparse data.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Speed-of-Sound Map Reconstruction on Breast USCT (test)](<https://www.sota2.com/research/sota/speed-of-sound-map-reconstruction-on-breast-usct-test.md>): Speed-of-Sound Map Reconstruction; Breast USCT (test); SSIM: 0.8431.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2407.14564>)

[PDF](<https://arxiv.org/pdf/2407.14564.pdf>)
