# MemFlow: Optical Flow Estimation and Prediction with Memory

Source: [MemFlow: Optical Flow Estimation and Prediction with Memory](<https://www.sota2.com/research/paper/68fa72cd1e209131cea58888>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-26T02:34:49.549Z

Authors: Qiaole Dong, Yanwei Fu

Published: 2024-04-07T04:56:58.000Z

## Abstract

Optical flow is a classical task that is important to the vision community. Classical optical flow estimation uses two frames as input, whilst some recent methods consider multiple frames to explicitly model long-range information. The former ones limit their ability to fully leverage temporal coherence along the video sequence; and the latter ones incur heavy computational overhead, typically not possible for real-time flow estimation. Some multi-frame-based approaches even necessitate unseen future frames for current estimation, compromising real-time applicability in safety-critical scenarios. To this end, we present MemFlow, a real-time method for optical flow estimation and prediction with memory. Our method enables memory read-out and update modules for aggregating historical motion information in real-time. Furthermore, we integrate resolution-adaptive re-scaling to accommodate diverse video resolutions. Besides, our approach seamlessly extends to the future prediction of optical flow based on past observations. Leveraging effective historical motion aggregation, our method outperforms VideoFlow with fewer parameters and faster inference speed on Sintel and KITTI-15 datasets in terms of generalization performance. At the time of submission, MemFlow also leads in performance on the 1080p Spring dataset. Codes and models will be available at: https://dqiaole.github.io/MemFlow/.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Optical Flow Estimation on MPI Sintel Clean (train)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-mpi-sintel-clean-train.md>): Optical Flow Estimation; MPI Sintel Clean (train); EPE: 0.85.

- [Optical Flow on SRFlow (test)](<https://www.sota2.com/research/sota/optical-flow-on-srflow-test.md>): Optical Flow; SRFlow (test); EPE: 0.5081.

- [Optical Flow on SRFlow](<https://www.sota2.com/research/sota/optical-flow-on-srflow.md>): Optical Flow; SRFlow; EPE: 0.2953.

- [Optical Flow on Spring (train)](<https://www.sota2.com/research/sota/optical-flow-on-spring-train.md>): Optical Flow; Spring (train); Bad Pixel Rate (Threshold 1.0): 3.24.

- [Optical Flow Estimation on KITTI-15 generalization (test)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-kitti-15-generalization-test.md>): Optical Flow Estimation; KITTI-15 generalization (test); Fl-epe: 3.88.

- [Optical Flow on Sintel Final](<https://www.sota2.com/research/sota/optical-flow-on-sintel-final.md>): Optical Flow; Sintel Final; EPE: 1.84.

- [Optical Flow Estimation on Sintel Final (test)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-sintel-final-test.md>): Optical Flow Estimation; Sintel Final (test); EPE: 1.83.

- [Optical Flow Estimation on MPI Sintel Final Pass](<https://www.sota2.com/research/sota/optical-flow-estimation-on-mpi-sintel-final-pass.md>): Optical Flow Estimation; MPI Sintel Final Pass; Overall AEE: 1.91.

- [Optical Flow Estimation on Sintel generalization Clean](<https://www.sota2.com/research/sota/optical-flow-estimation-on-sintel-generalization-clean.md>): Optical Flow Estimation; Sintel generalization Clean; EPE: 0.93.

- [Micro-expression Recognition on Composite Dataset](<https://www.sota2.com/research/sota/micro-expression-recognition-on-composite-dataset.md>): Micro-expression recognition; Composite Dataset; PM: 64.94.

- [Optical Flow Estimation on KITTI 2015 (test)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-kitti-2015-test.md>): Optical Flow Estimation; KITTI 2015 (test); Fl-all: 3.88.

- [Optical Flow on KITTI-15 (test)](<https://www.sota2.com/research/sota/optical-flow-on-kitti-15-test.md>): Optical Flow; KITTI-15 (test); Fl-all: 3.88.

- [Optical Flow Estimation on Composite Dataset (test)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-composite-dataset-test.md>): Optical Flow Estimation; Composite Dataset (test); PM: 0.6494.

- [Optical Flow on Spring (test)](<https://www.sota2.com/research/sota/optical-flow-on-spring-test.md>): Optical Flow; Spring (test); EPE: 0.471.

- [Point Tracking on TAP-Vid](<https://www.sota2.com/research/sota/point-tracking-on-tap-vid.md>): Point Tracking; TAP-Vid; DAVIS Score: 61.7.

- [Point Tracking on TAP-Vid RGB Stacking](<https://www.sota2.com/research/sota/point-tracking-on-tap-vid-rgb-stacking.md>): Point Tracking; TAP-Vid RGB Stacking; Avg Displacement Error: 85.2.

- [Optical Flow Estimation on KITTI 2015](<https://www.sota2.com/research/sota/optical-flow-estimation-on-kitti-2015.md>): Optical Flow Estimation; KITTI 2015; Fl-all: 4.1.

- [Optical Flow on Sintel Clean](<https://www.sota2.com/research/sota/optical-flow-on-sintel-clean.md>): Optical Flow; Sintel Clean; EPE: 1.046.

- [Optical Flow Estimation on Sintel Clean (test)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-sintel-clean-test.md>): Optical Flow Estimation; Sintel clean (test); EPE: 1.05.

- [Optical Flow Estimation on MPI Sintel Final (train)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-mpi-sintel-final-train.md>): Optical Flow Estimation; MPI Sintel Final (train); Endpoint Error (EPE): 2.06.

- [Micro-expression Recognition on SAMM (P\_M, R\_M, F1\_M, F1\_mu, G\_M)](<https://www.sota2.com/research/sota/micro-expression-recognition-on-samm-p_m-r_m-f1_m-f1_mu-g_m.md>): Micro-expression recognition; SAMM; F1 Score (Micro): 59.28.

- [Optical Flow on Sintel (train)](<https://www.sota2.com/research/sota/optical-flow-on-sintel-train.md>): Optical Flow; Sintel (train); AEPE (Clean): 0.85.

- [Optical Flow on KITTI (train)](<https://www.sota2.com/research/sota/optical-flow-on-kitti-train.md>): Optical Flow; KITTI (train); Fl-all: 0.137.

- [Optical Flow Estimation on KITTI 2015 (train)](<https://www.sota2.com/research/sota/optical-flow-estimation-on-kitti-2015-train.md>): Optical Flow Estimation; KITTI 2015 (train); Fl-epe: 3.38.

- [Optical Flow on KITTI 2015 (test)](<https://www.sota2.com/research/sota/optical-flow-on-kitti-2015-test.md>): Optical Flow; KITTI 2015 (test); Fl Error (All): not recorded.

- [Point Tracking on DAVIS TAP-Vid](<https://www.sota2.com/research/sota/point-tracking-on-davis-tap-vid.md>): Point Tracking; DAVIS TAP-Vid; Average Jaccard (AJ): not recorded.

- [Point Tracking on TAP-Vid Kinetics](<https://www.sota2.com/research/sota/point-tracking-on-tap-vid-kinetics.md>): Point Tracking; TAP-Vid Kinetics; Overall Accuracy: not recorded.

- [Point Tracking on RoboTAP](<https://www.sota2.com/research/sota/point-tracking-on-robotap.md>): Point Tracking; RoboTAP; AJ: not recorded.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2404.04808>)

[PDF](<https://arxiv.org/pdf/2404.04808.pdf>)
