# Human-level Performance On Automatic Head Biometrics In Fetal Ultrasound Using Fully Convolutional Neural Networks

Source: [Human-level Performance On Automatic Head Biometrics In Fetal Ultrasound Using Fully Convolutional Neural Networks](<https://www.sota2.com/research/paper/68fa64431e209131cea0392b>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T21:00:11.434Z

Authors: Matthew Sinclair, Christian F. Baumgartner, Jacqueline Matthew, Wenjia Bai, Juan Cerrolaza Martinez, Yuanwei Li, Sandra Smith, Caroline L. Knight, Bernhard Kainz, Jo Hajnal, Andrew P. King, Daniel Rueckert

Published: 2018-04-24T15:40:59.000Z

## Abstract

Measurement of head biometrics from fetal ultrasonography images is of key importance in monitoring the healthy development of fetuses. However, the accurate measurement of relevant anatomical structures is subject to large inter-observer variability in the clinic. To address this issue, an automated method utilizing Fully Convolutional Networks (FCN) is proposed to determine measurements of fetal head circumference (HC) and biparietal diameter (BPD). An FCN was trained on approximately 2000 2D ultrasound images of the head with annotations provided by 45 different sonographers during routine screening examinations to perform semantic segmentation of the head. An ellipse is fitted to the resulting segmentation contours to mimic the annotation typically produced by a sonographer. The model's performance was compared with inter-observer variability, where two experts manually annotated 100 test images. Mean absolute model-expert error was slightly better than inter-observer error for HC (1.99mm vs 2.16mm), and comparable for BPD (0.61mm vs 0.59mm), as well as Dice coefficient (0.980 vs 0.980). Our results demonstrate that the model performs at a level similar to a human expert, and learns to produce accurate predictions from a large dataset annotated by many sonographers. Additionally, measurements are generated in near real-time at 15fps on a GPU, which could speed up clinical workflow for both skilled and trainee sonographers.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Cardiac and thoracic ellipse detection on Clinical fetal echocardiogram (test)](<https://www.sota2.com/research/sota/cardiac-and-thoracic-ellipse-detection-on-clinical-fetal-echocardiogram-test.md>): Cardiac and thoracic ellipse detection; Clinical fetal echocardiogram (test); Dice (Thoracic): 87.5.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/1804.09102>)

[PDF](<https://arxiv.org/pdf/1804.09102.pdf>)