# Skin Lesion Analysis Towards Melanoma Detection Using Deep Learning Network

Source: [Skin Lesion Analysis Towards Melanoma Detection Using Deep Learning Network](<https://www.sota2.com/research/paper/68fa63cf1e209131cea00d19>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T20:49:10.785Z

Authors: Yuexiang Li, Linlin Shen

Published: 2017-03-02T01:24:04.000Z

## Abstract

Skin lesion is a severe disease in world-wide extent. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons, e.g. low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. International Skin Imaging Collaboration (ISIC) is a challenge focusing on the automatic analysis of skin lesion. In this paper, we proposed two deep learning methods to address all the three tasks announced in ISIC 2017, i.e. lesion segmentation (task 1), lesion dermoscopic feature extraction (task 2) and lesion classification (task 3). A deep learning framework consisting of two fully-convolutional residual networks (FCRN) is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU) is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. To our best knowledges, we are not aware of any previous work proposed for this task. The proposed deep learning frameworks were evaluated on the ISIC 2017 testing set. Experimental results show the promising accuracies of our frameworks, i.e. 0.718 for task 1, 0.833 for task 2 and 0.823 for task 3 were achieved.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Skin Lesion Segmentation on ISBI 2017](<https://www.sota2.com/research/sota/skin-lesion-segmentation-on-isbi-2017.md>): Skin Lesion Segmentation; ISBI 2017; JSI: 76.2.

- [Skin Lesion Segmentation on ISIC 2017 (test)](<https://www.sota2.com/research/sota/skin-lesion-segmentation-on-isic-2017-test.md>): Skin Lesion Segmentation; ISIC 2017 (test); Dice Score: not recorded.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/1703.00577>)

[PDF](<https://arxiv.org/pdf/1703.00577.pdf>)