# Modulating Thermometric Performance via Dopant Concentration and Morphology in Luminescence Thermometer Exhibiting Dual Structural Phase Transitions

Source: [Modulating Thermometric Performance via Dopant Concentration and Morphology in Luminescence Thermometer Exhibiting Dual Structural Phase Transitions](<https://www.sota2.com/research/paper/68fa4a5a1e209131ce93ddb7>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T07:47:55.950Z

Authors: Malgorzata Kubicka, Maja Szymczak, Maciej Ptak, Damian Szymanski, Vasyl Kinzhybahlo, Marek Drozd, Lukasz Marciniak

Published: 2025-05-20T05:35:39.000Z

## Abstract

Expanding the operational range of luminescent thermometers that utilize thermally induced structural phase transitions in lanthanide-doped materials necessitates the exploration of novel host matrices with diverse thermal behaviors. In line with this objective, the present study offers a comprehensive analysis of the temperature-dependent spectroscopic properties of Li3Sc2(PO4)3:Eu3+. The findings reveal that the studied material undergoes two reversible phase transitions: {\\gamma}LT - {\\alpha}/\\b{eta} phase transition at approximately 160 K, followed by an \\b{eta} HT transition around 550 K. These transitions are evidenced by notable alterations in the emission spectra and luminescence decay kinetics of Eu3+ ions. By employing an appropriate luminescence intensity ratio, the sensitivity was determined to be 7.8 % K-1 at 160 K for 0.1%Eu3+ and 0.65 % K-1 at 550 K for 0.5%Eu3+. Furthermore, the study demonstrates that the phase transition temperature in Li3Sc2(PO4)3:Eu3+ can be modulated through variations in dopant ion concentration and annealing conditions, which in turn influence the material's morphology. These strategies enable the fine-tuning of thermometric performance in phase transition-based luminescent thermometers. To the best of our knowledge, this represents the first report in the literature of a luminescent thermometer exhibiting dual thermal operating ranges.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2505.13956>)

[PDF](<https://arxiv.org/pdf/2505.13956.pdf>)
