# Ideal Conductor Model: An analytical finite-size correction for non-equilibrium molecular dynamics simulations of ion transport through nanoporous membranes

Source: [Ideal Conductor Model: An analytical finite-size correction for non-equilibrium molecular dynamics simulations of ion transport through nanoporous membranes](<https://www.sota2.com/research/paper/68fa433e1e209131ce9086fe>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T04:12:15.458Z

Authors: Brian A Shoemaker, Tiago S Domingues, Amir Haji-Akbari

Published: 2022-04-21T20:54:00.000Z

## Abstract

Modulating ion transport through nanoporous membranes is critical to many important chemical and biological separation processes. The corresponding transport timescales, however, are often too long to capture accurately using conventional molecular dynamics (\\textsc{Md}). Recently, path sampling techniques such as forward-flux sampling (\\textsc{Ffs}) have emerged as attractive alternatives for efficiently and accurately estimating arbitrarily long ionic passage times. Here, we use non-equilibrium \\textsc{Md} and \\textsc{Ffs} to explore how the kinetics and mechanism of pressure-driven chloride transport through a nanoporous graphitic membrane are affected by its lateral dimensions. We not only find ionic passage times and free energy barriers to decrease dramatically upon increasing the membrane surface area, but also observe an abrupt and discontinuous change in the locus of the transition state. These strong finite size effects arise due to the cumulative effect of the periodic images of the leading ion entering the pore on the distribution of the induced excess charge at the membrane surface in the feed. By assuming that the feed is an ideal conductor, we analytically derive a finite size correction term that can be computed from the information obtained from a single simulation and successfully use it to obtain corrected free energy profiles with no dependence on system size. We then estimate ionic passage times in the thermodynamic limit by assuming an Eyring-type dependence of rates on barriers with a size-independent prefactor. This approach constitutes a universal framework for removing finite size artifacts in molecular simulations of ion transport through nanoporous membranes and biological channel proteins.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2204.10405>)

[PDF](<https://arxiv.org/pdf/2204.10405.pdf>)
