# Development of low-background photomultiplier tubes for liquid xenon detectors

Source: [Development of low-background photomultiplier tubes for liquid xenon detectors](<https://www.sota2.com/research/paper/68fa3dba1e209131ce8e28fe>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T01:39:56.852Z

Authors: XMASS Collaboration, K. Abe, Y. Chen, K. Hiraide, K. Ichimura, S. Imaizumi, N. Kato, Y. Kishimoto, K. Kobayashi, M. Kobayashi, S. Moriyama, M. Nakahata, K. Sato, H. Sekiya, T. Suzuki, A. Takeda, S. Tasaka, M. Yamashita, B. S. Yang, N. Y. Kim, Y. D. Kim, Y. H. Kim, R. Ishii, Y. Itow, K. Kanzawa, K. Masuda, K. Martens, A. Mason, Y. Suzuki, K. Miuchi, Y. Takeuchi, K. B. Lee, M. K. Lee, Y. Fukuda, H. Ogawa, K. Nishijima, K. Fushimi, B. D. Xu, S. Nakamuran

Published: 2020-06-01T13:10:56.000Z

## Abstract

We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized a large photon acceptance and good timing resolution. Low radioactivity was achieved by three factors: (1) the glass material was synthesized using low-radioactive-contamination material; (2) the photocathode was produced with $^{39}$K-enriched potassium; and (3) the purest grade of aluminum material was used for the vacuum seal. As a result each R13111 PMT contains only about 0.4 mBq of $^{226}$Ra, less than 2 mBq of $^{238}$U, 0.3 mBq of $^{228}$Ra, 2 mBq of $^{40}$K and 0.2 mBq of $^{60}$Co. We also examined and resolved the intrinsic leakage of Xe gas into PMTs that was observed in several older models. We thus succeeded in developing a PMT that has low background, large angular acceptance with high collection efficiency, good timing resolution, and long-term stable operation. These features are highly desirable for experiments searching for rare events beyond the standard model, such as dark matter particle interactions and neutrinoless double beta decay events.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2006.00922>)

[PDF](<https://arxiv.org/pdf/2006.00922.pdf>)
