# Liquid argon scintillation response to electronic recoils between $2.8$--$1275~{\\rm keV}$ in a high light yield single-phase detector

Source: [Liquid argon scintillation response to electronic recoils between $2.8$--$1275~{\\rm keV}$ in a high light yield single-phase detector](<https://www.sota2.com/research/paper/68fa3d851e209131ce8e0e47>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T01:33:04.015Z

Authors: M.Kimura, K.Aoyama, M.Tanaka, K.Yorita

Published: 2020-03-31T14:33:43.000Z

## Abstract

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields $12.8 \\pm 0.3 ~ (11.2 \\pm 0.3)~{\\rm photoelectron/keV}$ for $511.0$-${\\rm keV}$ $\\gamma$-ray events based on a photomultiplier tube single photoelectron response modeling with a Gaussian plus an additional exponential term (with only a Gaussian term). It is exposed to a variety of calibration sources such as $^{22}{\\rm Na}$ and $^{241}{\\rm Am}$ $\\gamma$-ray emitters, and a $^{252}{\\rm Cf}$ fast neutron emitter that induces quasimonoenergetic $\\gamma$ rays through a $(n, n'\\gamma)$ reaction with $^{19}{\\rm F}$ in polytetrafluoroethylene. In addition, the high light detection efficiency of the detector enables identification of the $2.82$-${\\rm keV}$ peak of $^{37}{\\rm Ar}$, a cosmogenic isotope in atmospheric argon. The observed light yield and energy resolution of the detector are obtained by the full-absorption peaks. We find up to approximately $25\\%$ shift in the scintillation yield across the energy range and $3\\%$ of the energy resolution for the $511.0$-${\\rm keV}$ line. The Thomas-Imel box model with its constant parameter $\\varsigma=0.033 ^{+0.012} \_{-0.008}$ is found to explain the result. For liquid argon, this is the first measurement on the energy-dependent scintillation yield down to a few ${\\rm keV}$ at null field and provides essential inputs for tuning the argon response model to be used for physics experiments.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2003.14248>)

[PDF](<https://arxiv.org/pdf/2003.14248.pdf>)
