# Ultrafast photocurrent and absorption microscopy of few-layer TMD devices isolate rate-limiting dynamics driving fast and efficient photoresponse

Source: [Ultrafast photocurrent and absorption microscopy of few-layer TMD devices isolate rate-limiting dynamics driving fast and efficient photoresponse](<https://www.sota2.com/research/paper/68fa3cc91e209131ce8dd519>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-25T01:20:01.811Z

Authors: Kyle T. Vogt, Su-Fei Shi, Feng Wang, Matt W. Graham

Published: 2020-03-30T15:54:35.000Z

## Abstract

Despite inherently poor interlayer conductivity, photodetectors made from few-layer devices of 2D transition metal dichalcogenides (TMDs) such as WSe$\_2$ and MoS$\_2$ can still yield a desirably fast ($\\leq$90 ps) and efficient ($\\epsilon$$\>$40\\%) photoresponse. By combining ultrafast photocurrent (U-PC) and transient absorption (TA) microscopy, the competing electronic escape and recombination rates are unambiguously identified in otherwise complex kinetics. Both the U-PC and TA response of WSe$\_2$ yield matching interlayer electronic escape times that accelerate from 1.6 ns to 86 ns with applied $E$-field to predict the maximum device PC-efficiency realized of $\\sim$44\\%. The slope of the escape rates versus $E$-field suggests out-of-plane electron and hole mobilities of 0.129 and 0.031 cm$^2$/V$s$ respectively. Above $\\sim$10$^{11}$ photons/cm$^{2}$ incident flux, defect-assisted Auger scattering greatly decreases efficiency by trapping carriers at vacancy defects. Both TA and PC spectra identify a metal-vacancy sub-gap peak with $\\sim$5.6 ns lifetime as a primary trap capturing carriers as they hop between layers. Synchronous TA and U-PC microscopy show the\\ net PC collected is modelled by a kinetic rate-law of electronic escape competing against the linear and nonlinear Auger recombination rates. This simple rate-model further predicts the PC-based dynamics, nonlinear amplitude and efficiency, $\\epsilon$ over a 10$^5$ range of incident photon flux in few-layer WSe$\_2$ and MoS$\_2$ devices.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/2003.13579>)

[PDF](<https://arxiv.org/pdf/2003.13579.pdf>)
