# A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector

Source: [A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector](<https://www.sota2.com/research/paper/68fa34091e209131ce894fd5>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-24T20:24:08.361Z

Authors: XMASS Collaboration: H. Takiya, K. Abe, K. Hiraide, K. Ichimura, Y. Kishimoto, K. Kobayashi, M. Kobayashi, S. Moriyama, M. Nakahata, T. Norita, H. Ogawa, H. Sekiya, O. Takachio, A. Takeda, S. Tasaka, M. Yamashita, B. S. Yang, N. Y. Kim, Y. D. Kim, Y. Itow, R. Kegasa, K. Kobayashi, K. Masuda, K. Fushimi, K. Martens, Y. Suzuki, R. Fujita, K. Hosokawa, K. Miuchi, N. Oka, Y. Onishi, Y. Takeuchi, Y. H. Kim, J. S. Lee, K. B. Lee, M. K. Lee, Y. Fukuda, K. Nishijima, S. Nakamura

Published: 2016-04-06T06:22:00.000Z

## Abstract

We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $\\tau\_1$ and $\\tau\_2$, the decay time constant $\\tau\_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $\\tau\_1 \\sim 2$ ns was necessary to reproduce data. Energy dependencies of $\\tau\_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/1604.01503>)

[PDF](<https://arxiv.org/pdf/1604.01503.pdf>)