# Discrete, 3D distributed, linear imaging methods of electric neuronal activity. Part 1: exact, zero error localization

Source: [Discrete, 3D distributed, linear imaging methods of electric neuronal activity. Part 1: exact, zero error localization](<https://www.sota2.com/research/paper/68fa21277a2b558e2933572c>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-28T13:52:12.409Z

Authors: Roberto D. Pascual-Marqui

Published: 2007-10-17T16:14:50.000Z

## Abstract

This paper deals with the EEG/MEG neuroimaging problem: given measurements of scalp electric potential differences (EEG: electroencephalogram) and extracranial magnetic fields (MEG: magnetoencephalogram), find the 3D distribution of the generating electric neuronal activity. This problem has no unique solution. Only particular solutions with "good" localization properties are of interest, since neuroimaging is concerned with the localization of brain function. In this paper, a general family of linear imaging methods with exact, zero error localization to point-test sources is presented. One particular member of this family is sLORETA (standardized low resolution brain electromagnetic tomography; Pascual-Marqui, Methods Find. Exp. Clin. Pharmacol. 2002, 24D:5-12; http://www.unizh.ch/keyinst/NewLORETA/sLORETA/sLORETA-Math01.pdf). It is shown here that sLORETA has no localization bias in the presence of measurement and biological noise. Another member of this family, denoted as eLORETA (exact low resolution brain electromagnetic tomography; Pascual-Marqui 2005: http://www.research-projects.unizh.ch/p6990.htm), is a genuine inverse solution (not merely a linear imaging method) with exact, zero error localization in the presence of measurement and structured biological noise. The general family of imaging methods is further extended to include data-dependent (adaptive) quasi-linear imaging methods, also with the exact, zero error localization property.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

- [Source Localization on 2000 single source activations 20 dB SNR (val)](<https://www.sota2.com/research/sota/source-localization-on-2000-single-source-activations-20-db-snr-val.md>): Source Localization; 2000 single source activations 20 dB SNR (val); EMD: 0.58.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/0710.3341>)

[PDF](<https://arxiv.org/pdf/0710.3341.pdf>)
