# Thermal recovery of colour centres induced in cubic yttria-stabilized zirconia by charged particle irradiations

Source: [Thermal recovery of colour centres induced in cubic yttria-stabilized zirconia by charged particle irradiations](<https://www.sota2.com/research/paper/68fa206e7a2b558e29330f7c>)

Collection index: [llms.txt](<https://www.sota2.com/research/llms.txt>)

Data updated: 2025-10-23T21:59:17.965Z

Authors: Francois Beuneu, Jean-Marc Costantini

Published: 2006-03-31T09:50:31.000Z

## Abstract

We have used electron paramagnetic resonance to study the thermal annealing of colour centres induced in cubic yttria-stabilized zirconia by swift electron and heavy ion-irradiations. Single crystals were irradiated with 1 or 2-MeV electrons, and 200-MeV 127I, or 200-MeV 197Au ions. Electron and ion beams produce the same colour centres: namely i) an F+-like centre, ii) the so-called T-centre (Zr3+ in a trigonal oxygen local environment), and iii) a hole center. Isochronal annealing was performed up to 973 K. Isothermal annealing was performed at various temperatures on samples irradiated with 2-MeV electrons. The stability of paramagnetic centres increases with fluence and with a TCR treatment at 1373 K under vacuum prior to the irradiations. Two distinct recovery processes are observed depending on fluence and/or thermal treatment. The single-stage type I process occurs for F+-like centres at low fluences in as-received samples, and is probably linked to electron-hole recombination. T-centres are also annealed according to a single-stage process regardless of fluence. The annealing curves allow one to obtain activation energies for recovery. The two-stage type II process is observed only for the F+-like centres in as-received samples, at higher fluences, or in reduced samples. These centres are first annealed in a first stage below 550 K, like in type I, then transform into new paramagnetic centres in a second stage above 550 K. A simple kinetics model is proposed for this process. Complete colour centre bleaching is achieved at about 1000 K.

## Recorded benchmark results

A research result applies to its stated dataset, split, metric and evaluation configuration. Compare like-for-like settings, preserve the metric's unit and direction, and distinguish paper-reported results from independent reproduction. The best result recorded here is not a claim of exhaustive, current global coverage.

## Original sources and implementation

[Original paper](<https://arxiv.org/abs/cond-mat/0603848>)

[PDF](<https://arxiv.org/pdf/cond-mat/0603848.pdf>)
